Diagram Skema Wiring Bench Power Supply
1. Jalur Power & Standby
- PS_ON (Hijau): Ke saklar → GND.
- PWR_OK (Abu): LED + resistor 220Ω → GND.
2. Output Tetap
- 3.3V → Oranye → Terminal Merah #1
- 5V → Merah → Terminal Merah #2
- 12V → Kuning → Terminal Merah #3
- GND → Hitam → Terminal Hitam
3. Output Variabel
| Dari | Ke | Catatan |
| PSU +12V | Buck IN + | Kuning |
| PSU GND | Buck IN - | Hitam |
| PSU +5V | Power Meter | Merah Tipis |
| Meter Ampere | Output + | Kuning Tipis |
| Buck OUT + | Fuse | 5A |
| Fuse | Output + | Sensing |
| Buck OUT - | Shunt Meter | Hitam Tebal |
| Meter Out | Output - | Merah Tebal |
PENTING!
- Beban Dummy: Jika tegangan 12V tidak stabil, beri beban (resistor 10 Ohm 10W) pada jalur 5V.
- Isolasi: Gunakan Heat Shrink pada semua sambungan solder untuk menghindari korsleting dengan casing metal.
- Fuse: Pilih nilai fuse sedikit di bawah arus maksimal Buck Converter (misal: Buck 5A, gunakan fuse 4A).
- Grounding: Pastikan kabel hitam tebal yang digunakan untuk jalur arus cukup besar agar tidak panas saat beban tinggi.
Bench Power Supply Wiring Diagram
1. Power & Standby (Mandatory)
- PS_ON (Green): Connect to toggle switch → GND.
- PWR_OK (Gray): LED + 220Ω resistor → GND.
2. Fixed Outputs
- 3.3V → Orange → Red Binding Post #1
- 5V → Red → Red Binding Post #2
- 12V → Yellow → Red Binding Post #3
- GND → Black wires → Main Black Binding Post
3. Adjustable Output
| From | To | Notes |
| PSU +12V | Buck IN + | Yellow |
| PSU GND | Buck IN - | Black |
| PSU +5V | Meter Power | Thin Red |
| Meter Ampere | Output + | Thin Yellow |
| Buck OUT + | Fuse | 5A |
| Fuse | Output + | Sensing wire |
| Buck OUT - | Meter Shunt In | Thick Black |
| Meter Out | Output - | Thick Red |
Important Notes
- Dummy Load: If the 12V voltage is unstable, add a load (10 Ohm 10W resistor) to the 5V line.
- Insulation: Use Heat Shrink on all solder joints to prevent shorting with the metal casing.
- Fuse: Select a fuse rating slightly below the maximum current of the Buck Converter (e.g., if you want to buck 5A, use a 4A fuse).
- Grounding: Make sure the thick black wire used for the current path is large enough to prevent overheating under high loads.